Features:
- Radial Metallized Polypropylene Film
- Class X2 (across - the - line)
- Self Healing, Extended Foil, Non-Inductive
- Case meets UL 94V-0 Flammability Spec
International approvals:

Specifications:
Capacitance Values*:
0.01 F to 1.0 F
Tolerances: ± 20% (M), ± 10% (K), ± 5% (J)
Working Voltage: 250/275Vac @ 50-60Hz
Withstand Voltage: Applied 1200Vac @ 60 sec.or 2100Vdc for 1 sec.
Dissipation Factor: (tan d): £ 0.1% at 1Khz and 25°C
Operating Temp Range: -40°C to 100°C derate voltage 1.5% / °C
over 85°C to 100°C
Climatic Category: -40°C / +85°C / 56 days (@ R. H. £
75%)
Humidity Category: Average relative humidity £
75%
95% for 30 days per year continuously
85% for the remaining days occasionally
Construction Data: Style: Non-Inductively wound, Radial Leads
Encapsulation: Plastic case & Flame retardant resin (UL94V-0)
Leads: Tinned, Copperweld or Copper Wire
Bare or insulated wires available
Self Inductance: Approx. 10nH/.08(2) of case plus wire length
Insulation Resistance: (see Table)
*Other values are available.
Ordering Lead Code:
* Choose a letter from the following:
HQX-I = insulated wires
HQX-R = bare wires, long
HQX-S = bare wires, short
Insulation
Resistance |
| Rated Vac |
250/275 |
| Charging Vdc (for 1 min.) |
100 +
15 |
Capacity F |
< .33 |
> .33 |
IR M
 |
> 30000 |
|
IR sec. (M
x F) |
|
> 10000 |
|




|